Type SOOW 600 Volts CSA UL

 

Fully-annealed, stranded bare copper per ASTM B-174, premium grade colour-coded 90ºC synthetic rubber insulation, oil resistant Thermoset (Black CPE) jacket. -40° C to 90° C, 600 Volts, CSA FT1 and UL approved, sunlight, water, and weather resistant per UL & CSA.

Packaging: 300m, 150m & 75m spools, or cut to length.

Applications:

Jacket Colour & Imprint Options:

ECS
Catalogue
Number
Conductor AMPS* Wall Thickness Nominal
O.D.
(inches)
Total
Weight
(lbs/km)

Colour Code Chart
No. AWG
Size
Stranding Insulation
(inches)
Jacket
(inches)
SOW18-02 2 18 16 x 30 10 .030 .060 .340 151 1
SOW18-03 3 18 16 x 30 10 .030 .060 .360 190 1
SOW18-04 4 18 16 x 30 7 .030 .060 .385 250 1
SOW18-05 5 18 16 x 30 5.6 .030 .080 .465 390 1
SOW16-02 2 16 26 x 30 13 .030 .060 .365 184 1
SOW16-03 3 16 26 x 30 13 .030 .060 .385 248 1
SOW16-04 4 16 26 x 30 10 .030 .060 .410 315 1
SOW16-05 5 16 26 x 30 8 .030 .080 .490 515 1
SOW14-02 2 14 41 x 30 18 .045 .080 .495 250 1
SOW14-03 3 14 41 x 30 18 .045 .080 .520 324 1
SOW14-04 4 14 41 x 30 15 .045 .080 .560 397 1
SOW14-05 5 14 41 x 30 12 .045 .095 .635 832 1
SOW12-02 2 12 65 x 30 25 .045 .095 .565 371 1
SOW12-03 3 12 65 x 30 25 .045 .095 .590 466 1
SOW12-04 4 12 65 x 30 20 .045 .095 .640 587 1
SOW12-05 5 12 65 x 30 16 .045 .095 .705 1,145 1
SOW10-02 2 10 104 x 30 30 .045 .095 .615 607 1
SOW10-03 3 10 104 x 30 30 .045 .095 .650 784 1
SOW10-04 4 10 104 x 30 25 .045 .095 .700 1,171 1
SOW10-05 5 10 104 x 30 20 .045 .095 .760 1,512 1
SOW08-03 3 8 133 x 29 40 .045 .095 .835 1,565 1
SOW08-04 4 8 133 x 29 35 .045 .095 .930 1,985 1
SOW08-05 5 8 133 x 29 40 .060 .095 1.057 2,296 1
SOW06-03 3 6 133 x 27 55 .045 .095 .975 2,224 1
SOW06-04 4 6 133 x 27 45 .045 .095 1.055 2,808 1
SOW06-05 5 6 133 x 27 36 .060 .095 1.225 3,379 1
SOW04-03 3 4 133 x 25 70 .045 .095 1.135 3,379 1
SOW04-04 4 4 133 x 25 60 .045 .095 1.255 4,255 1
SOW04-05 5 4 133 x 25 48 .060 .095 1.373 4,255 1
SOW02-04 4 2 133 x .23 80 .045 .095 1.455 5,800 1
SOW02-05 5 2 133 x .23 65 .060 .095 1.610 6,562 1

 

*Ampacities (Amps per conductor) are based on 30°C ambient temperature in air per the 1999 NEC, Table 400-5(A). Ampacities for 3/C and 4/C cords assume 1 conductor is used as a ground or neutral and does not carry current. Ampacities for 5/C cords assume 2 conductors are used as ground and neutral and do not carry current.

 

Applications:

Designed for extra hard usage with industrial equipment, heavy tools, battery chargers, portable lights and power extensions.

 

ECS can custom colour or imprint your Portable Cord jacket